709H - 

Precision Hart Loop Calibrator

Fluke 709H
聲明:圖片僅供參考,請以實物為準!
制造商:
Fluke Fluke
制造商產(chǎn)品編號:
709H
倉庫庫存編號:
70272100
技術(shù)數(shù)據(jù)表:
View 709H Datasheet Datasheet
訂購熱線: 400-900-3095  0755-21000796, QQ:800152669, Email:sales@szcwdz.com
由于產(chǎn)品數(shù)據(jù)庫龐大,部分產(chǎn)品信息可能未能及時更新,下單前請與銷售人員確認好實時在庫數(shù)量,謝謝合作!

709H產(chǎn)品概述

Fluke reliable. HART compatible.
Fluke puts HART communication in a precision loop calibrator.

The Fluke 709 and 709H mA loop calibrators are designed to save time and produce high-quality results. These calibrators are built around a user friendly interface with a quick-set rotary encoder knob. This tool reduces the time it takes to measure, or source, current and power up a loop. The protective holster easily fits into a technician's hand and the large backlit display is easy to read, even in dark, cramped worked areas.

Features:
  • Best-in-class accuracy at 0.01% reading
  • Compact rugged design
  • Intuitive user interface with quick-set knob for fast setup, easy use
  • 24 V dc loop power with mA measure mode (–25% to 125%)
  • Resolution of 1 μA on mA ranges and 1 mV on voltages ranges
  • Built in selectable 250 Ω resistor for HART communications
  • Simple two wire connection for all measurements
  • Auto shutdown to conserve battery life
  • Variable step and ramp time in seconds
  • Valve test (source and simulate defined mA values with % keys)

    HART communication
    The Fluke 709H offers a built-in HART modem for communication capability to perform the following commands:
  • Read message
  • Read tag, descriptor, calibration date
  • Read sensor PV information
  • Read PV output information
  • Read long tag
  • Write PV ranges (upper and lower)
  • Enter/exit fixed current mode
  • Set zero offset
  • Trim DAC zero (mA output 4 mA)
  • Trim DAC gain (mA output 20 mA)
  • The Fluke 709H also offers ability to store up to twenty HART device configuration files for uploading via 709H/TRACK software. Configurations can be stored as .csv or .txt files. This allows the end user to document plant HART easily.

    Configurations can be stored as .csv or .txt files. This feature gives the technician direct access to key device parameters, allowing better troubleshooting, calibrating and maintaining of plant assets.