amphenol代理商
專業(yè)銷售Amphenol(安費(fèi)諾)全系列產(chǎn)品-英國2號(hào)倉庫
美國1號(hào)分類選型新加坡2號(hào)分類選型英國10號(hào)分類選型英國2號(hào)分類選型日本5號(hào)分類選型

在本站結(jié)果里搜索:    
熱門搜索詞:  Connectors  8910DPA43V02  Amphenol  UVZSeries 160VDC  70084122  IM21-14-CDTRI

2CPSA1B1 - 

Safety Switch, Cable Pull, 2 direction, 2NC/2NO, 0.5in. NPT, Gold Plate Contact

Honeywell 2CPSA1B1
聲明:圖片僅供參考,請(qǐng)以實(shí)物為準(zhǔn)!
制造商產(chǎn)品編號(hào):
2CPSA1B1
倉庫庫存編號(hào):
70118849
技術(shù)數(shù)據(jù)表:
View 2CPSA1B1 Datasheet Datasheet
訂購熱線: 400-900-3095  0755-21000796, QQ:800152669, Email:sales@szcwdz.com
由于產(chǎn)品數(shù)據(jù)庫龐大,部分產(chǎn)品信息可能未能及時(shí)更新,下單前請(qǐng)與銷售人員確認(rèn)好實(shí)時(shí)在庫數(shù)量,謝謝合作!

2CPSA1B1產(chǎn)品概述

MICRO SWITCH 2CPS Series Cable Pull Safety Switch, Cable, Maintained Both Sides, 2NC/2NO Direct Opening (Switch 2, Left: 1NC/1NO; Switch 2, Right: 1NC/1NO), 1/2 NPT, Gold-plated Contacts, 120 Vac Multi-cluster LED. The 2CPS Cable Pull Safety Switch provides readily accessible emergency stop over a long, linear distance. It is a cost-effective means of providing this emergency stop signal compared to multiple emergency stop push buttons. (Cable Pull Safety Switches are not, however, to be used as a means of personnel safeguarding. They may be used to prevent further injury or damage to equipment when used for emergency stop signaling.)
The 2CPS Series Cable Pull Safety Switch is designed to provide emergency stop protection for exposed conveyor lines. The internal mechanism latches on both slackened cable (push) and pulled cable. This capability enhances productivity by eliminating nuisance stops due to variations in temperature, stretch of cable over time, and other application variables.
A line in the midpoint of the cable tension window indicates proper cable tension, providing easy and intuitive set-up. The direct acting switch contacts are held closed when the actuating cable is under proper tension and the reset knob is set to RUN. When the actuating cable is pulled, slackened or broken, a cam positively opens the NC (Normally Closed) switch contacts. The snap action, trip operation causes the switch contacts to change state and mechanically latch almost simultaneously when the cable is pulled, slackened or broken. The NC switch contacts remain open until the 2CPS is reset by properly tensioning the cable and manually rotating the reset knob.
When the direct acting switch contacts open, the auxiliary contacts also actuate (open contacts close and closed contacts open). The auxiliary contacts are electrically isolated from the direct acting switch contacts. These NO (Normally Open) contacts may be used for monitoring or signaling.
The 2CPS complies with: Low Voltage Directive 73/23/EEC, as amended by directive 93/68/EEC; Machinery Directive 98/37/EEC only as the directives relate to the components being used in a safety function; IEC/EN60947-1; IEC/EN60947-5-1; IEC/EN60947-5-5; UL, CE, CSA, SIL 3 capable.


Features:
  • Positive opening operation of normally closed contacts
  • Choice of 2NC/2NO or 3NC/1NO contact configurations
  • Maximum cable length in a single direction is 76 m (250 ft) for a combined length of 152 m (500 ft) in dual directions
  • Choice of three actuator configurations
  • Removable contact block version available
  • Large wiring cavity with straight-through wiring
  • 24 Vdc or 120 Vac bright, multi-cluster LED status indicator light available
  • Gold-plated contacts are standard
  • Die-cast zinc housing
  • Optional hardware packs available
  • UL, CE, CSA, SIL 3 capable

    Applications
  • Long conveyor systems found in warehouses and distribution centers
  • Conveyor systems having a high amount of vibration
  • Conveyor systems that experience wide temperature swings
  • Long conveyor systems where easy through wiring, or highly visible trip status is required
  • Perimeter guarding where hosedown conditions are present
  • 2CPSA1B1產(chǎn)品信息

      Application  Long conveyor systems found in warehouses and distribution centers, Conveyor systems having a high amount of vibration, Conveyor systems that experience wide temperature swings  
      Brand/Series  2CPS Series  
      Contact Form  1 NO, 3 NC  
      Force, Operating  Operating force to actuate switch: 40 LBS. Force to maintain switch at proper tension: 25 LBS.  
      Function  Safety  
      IP Rating  IP67  
      Material  Zinc Die-Cast  
      Operation  Latched when tripped from either direction  
      Plating, Contact  Gold  
      Standards  BG, UL, CSA, CE Approved  
      Voltage Rating  240 VAC  
    關(guān)鍵詞         

    2CPSA1B1產(chǎn)品配件

    • 參考圖片
    • 制造商 / 說明 / 型號(hào) / 倉庫庫存編號(hào)
    • PDF
    • 操作

    2CPSA1B1關(guān)聯(lián)產(chǎn)品

    2CPSA1B1相關(guān)搜索

    Application Long conveyor systems found in warehouses and distribution centers, Conveyor systems having a high amount of vibration, Conveyor systems that experience wide temperature swings  Honeywell Application Long conveyor systems found in warehouses and distribution centers, Conveyor systems having a high amount of vibration, Conveyor systems that experience wide temperature swings  Cable Pull Application Long conveyor systems found in warehouses and distribution centers, Conveyor systems having a high amount of vibration, Conveyor systems that experience wide temperature swings  Honeywell Cable Pull Application Long conveyor systems found in warehouses and distribution centers, Conveyor systems having a high amount of vibration, Conveyor systems that experience wide temperature swings   Brand/Series 2CPS Series  Honeywell Brand/Series 2CPS Series  Cable Pull Brand/Series 2CPS Series  Honeywell Cable Pull Brand/Series 2CPS Series   Contact Form 1 NO, 3 NC  Honeywell Contact Form 1 NO, 3 NC  Cable Pull Contact Form 1 NO, 3 NC  Honeywell Cable Pull Contact Form 1 NO, 3 NC   Force, Operating Operating force to actuate switch: 40 LBS. Force to maintain switch at proper tension: 25 LBS.  Honeywell Force, Operating Operating force to actuate switch: 40 LBS. Force to maintain switch at proper tension: 25 LBS.  Cable Pull Force, Operating Operating force to actuate switch: 40 LBS. Force to maintain switch at proper tension: 25 LBS.  Honeywell Cable Pull Force, Operating Operating force to actuate switch: 40 LBS. Force to maintain switch at proper tension: 25 LBS.   Function Safety  Honeywell Function Safety  Cable Pull Function Safety  Honeywell Cable Pull Function Safety   IP Rating IP67  Honeywell IP Rating IP67  Cable Pull IP Rating IP67  Honeywell Cable Pull IP Rating IP67   Material Zinc Die-Cast  Honeywell Material Zinc Die-Cast  Cable Pull Material Zinc Die-Cast  Honeywell Cable Pull Material Zinc Die-Cast   Operation Latched when tripped from either direction  Honeywell Operation Latched when tripped from either direction  Cable Pull Operation Latched when tripped from either direction  Honeywell Cable Pull Operation Latched when tripped from either direction   Plating, Contact Gold  Honeywell Plating, Contact Gold  Cable Pull Plating, Contact Gold  Honeywell Cable Pull Plating, Contact Gold   Standards BG, UL, CSA, CE Approved  Honeywell Standards BG, UL, CSA, CE Approved  Cable Pull Standards BG, UL, CSA, CE Approved  Honeywell Cable Pull Standards BG, UL, CSA, CE Approved   Voltage Rating 240 VAC  Honeywell Voltage Rating 240 VAC  Cable Pull Voltage Rating 240 VAC  Honeywell Cable Pull Voltage Rating 240 VAC  
    電話:400-900-3095
    QQ:800152669
    關(guān)于我們 | Amphenol簡(jiǎn)介 | Amphenol產(chǎn)品 | Amphenol產(chǎn)品應(yīng)用 | Amphenol動(dòng)態(tài) | 按系列選型 | 按產(chǎn)品規(guī)格選型 | Amphenol選型手冊(cè) | 付款方式 | 聯(lián)系我們
    Copyright © 2017 m.training-know-how.com All Rights Reserved. 技術(shù)支持:電子元器件 ICP備案證書號(hào):粵ICP備11103613號(hào)